ESL Power

An Employee Owned Company

Contact Us: (800) 922-4188

REQUEST A QUOTE ESL CAREERS

Search

MENUMENU
  • Home
  • Products
        • Intermodal/Reefer
          • Standard Reefer Outlets
          • Rear Actuated Reefer Assemblies
          • Non-modular Reefer Outlet Assemblies
          • Port Terminal Reefer Outlet Assemblies
          • Shipboard
          • Railroad
          • Plugs and Connectors
          • Cord Sets and Splice Kits
          • Portable Reefer Sharing Units
          • Modular Reefer Sharing Units
          • Transformers
        • Emergency Power
          • Generator Dealer Resources
          • Manual Transfer Switch - StormSwitch
          • Compact Manual Transfer Switch - StormSwitch BeBe
          • Rotary Manual Transfer Switch - RotaryConnect
          • 3-Way Manual Transfer Switch - TripleSwitch
          • Dual Purpose Docking Station - DualConnect
          • Automatic Transfer Switch with Cams - ReadyConnect
          • Generator Docking Stations - TempTap
          • Outlet Distribution Units - OutTap
          • Generator Connection Box - DirecTap
          • Custom Emergency Solutions
        • Ship-to-Shore Power
          • Military Ship-to-Shore Power
          • Commercial Ship Shore Power & Connection Solutions
        • eTRU Shore Power
          • Automatic Conductive Charging
          • eTRUconnect® PS Series
          • eTRUconnect® MC Series
          • Shore Power Kits for Refrigerated Truck-Trailer Units
          • Truck Shore Power for Box Trucks with eTRUconnect®
          • Savings Calculator
        • Entertainment Power
          • Standard Company Switch - ShowSwitch
          • Outdoor Company Switch
          • Flush Mount Company Switch
          • Dual Chamber Company Switch
          • Combo Company Switches
          • Power Distribution Boards
          • Pin & Sleeve Theatre Outlet (60A & 100A)
        • Wayside Power Cabinets
        • ERTG Disconnect
        • Shipyard Power
        • Industrial/Portable Power
        • Custom Solutions
  • Catalog
        • Intermodal / Reefer
          • Safety-interlocked Reefer Outlets
          • Reefer Outlet Assemblies
          • Rack/Wall Mount
          • Bunker Mount
          • Pole Mount
          • Portable
          • Power Pack Panels
          • Pedestal
          • Plugs
          • Connectors
          • Accessories
          • Extension Cords
          • Converter Cords
          • Phase Rotation Test Plugs
          • Y-Splitters
          • Conversion Kits
          • Covers
          • Cable Splice Kits
          • Reefer Sharing Units
          • Reefer Transformers
        • Shore Power
          • Military
          • Mil-C 24368 Plugs
          • Mil-C 24368 Receptacles
          • Cable Assemblies
          • Outlet Assemblies
          • 500V
          • 600V
          • Shore Power Mound Assemblies
          • Commercial
          • Shipyard / Industrial
          • Power Outlets
          • Assemblies
          • Plugs
        • Truck-trailer Shore Power
        • Emergency Power
          • StormSwitch
          • TempTap
          • RotaryConnect
          • TripleSwitch
          • DualConnect
          • ReadyConnect
          • DirecTap
          • OutTap
        • Entertainment Power
          • Company Switches
          • Pin and Sleeve
          • Concert Power Distribution Boards
        • Wayside Power
          • Cabinets
        • ERTG Disconnect
  • Videos
        • Quality of Service
        • Q Reefer Outlet
        • Reefer Sharing Unit
        • TripleSwitch Application
        • Simplify Generator Load Bank Testing
        • StormSwitch Demo
        • StormSwitch No Power
        • ShowSwitch Demo
        • Refrigerated Truck-Trailer Shore Power
        • Refrigerated Truck-Trailer Kits
        • ERTG
        • Plug Install
        • Cable Splice Kit Demo
        • ESL Virtual Tour Video
        • Custom Control Panel Shop Tour
        • Electrical Control Panel Design Considerations Video Series
        • Contract Manufacturing Capabilities
        • Recent Videos

          Refrigerated Truck-trailer Shore Power

          ESL's Q Module

          ESLs Q Reefer Outlet

        • DualConnect
  • Company
    • About ESL Power Systems, Inc.
    • Press Releases/Articles
    • Webinars
  • Blog
  • Contact
        • ESL Contact Information
        • How to Buy Our Products
          • Request a Quote for Intermodal
          • Request a Quote for Emergency Power
          • Request a Quote for Entertainment Power
          • Request a Quote for Shore Power
          • Request a Quote for Refrigerated Truck-trailer Shore Power
          • Request a Quote for Custom Control Panels
          • Request a Quote for Wayside Cabinets
        • Request More Information
  • Careers
  • English

Dual Purpose Docking Station
Standard Specifications

More Info

  • Dual Purpose Docking Station
  • Features
  • Specifications
    • Download PDF
    • Download DOC
  • Panel Layout Drawings
    DPDS Single Line Diagram
  • Emergency Solutions Single Lines
  • NEC 700.3(F)
  • FAQ’s
  • Brochure
  • Product Catalog
Get Custom Quote

Dual Purpose Docking Station Standard Specifications

Dual Purpose Docking Station Standard Specs (PDF)
Dual Purpose Docking Station Standard Spec (DOC)
(revised as of 10/18/21)

SECTION 1 – GENERAL REQUIREMENTS

1.01 Scope:

A. Contractor shall furnish, deliver, install and test the dual purpose docking station as specified herein and in accordance with the drawings.

1.02 Quality Assurance:

A. Dual purpose docking station shall be UL listed and labeled under the UL 1008 standard.

B. Dual purpose docking station manufacturer shall provide a complete factory assembled, wired and tested dual purpose docking station.

C. Dual purpose docking station shall be factory Hi-pot tested for a period of not less than 60 seconds.

D. Dual purpose docking station installation shall meet all applicable NEC standards.

1.03 Submittals:

A. Contractor shall submit manufacturer’s drawings and data of dual purpose docking stations for Engineer’s approval prior to start of fabrication.  Drawings and data shall include, as a minimum, dimensioned general arrangement drawings and wiring diagrams, UL listing information including UL file or control number, short circuit rating or withstand rating, component data, mounting provisions, conduit entry locations and installation instructions.

B. Upon installation of dual purpose docking stations Contractor shall submit manufacturer’s Operating & Maintenance Manual which shall include as a minimum:
1. Certified as-built General Arrangement drawings and Wiring Diagram.
2. Materials / Component List including part numbers.
3. Maintenance and service requirements.
4. Certificate of Compliance and hi-pot test data.

1.04 Warranty:

A. Dual purpose docking stations shall be covered by manufacturer’s warranty for a minimum period of (1) one year after shipment from manufacturer.

SECTION 2 – PRODUCTS

2.01 General:

A. All equipment shall be new.

B. Dual purpose docking station manufacturer must have produced and sold UL 1008 Listed dual purpose docking stations as a standard product for minimum of (3) years.

C. Dual purpose docking stations provided with overcurrent protection devices shall be molded case circuit breaker type; knife switch or fused switches are not acceptable.

D. Contractor shall be responsible for the equipment until it has been installed and is finally inspected, tested and accepted in accordance with the requirements of this Specification.

E. Dual purpose docking stations shall be DualConnect™ as manufactured by ESL Power Systems, Inc. or equal as approved by the Engineer.

2.02 Dual Purpose Docking Stations:

A.  2-breaker dual purpose docking station shall consist of (2) molded case circuit breakers, Load bank breaker to be provided with a shunt trip (shunt trip voltage to be per the drawings), male cam-style inlet connectors, female cam-style outlet connectors, power distribution blocks and grounding terminals, all housed within a padlockable enclosure.

B. 1-breaker dual purpose docking station shall consist of (1) molded case circuit breakers, male cam-style inlet connectors, female cam-style outlet connectors, power distribution blocks and grounding terminals, all housed within a padlockable enclosure.

C. No-breaker dual purpose docking station shall consist of male cam-style inlet connectors, female cam-style outlet connectors, power distribution blocks and grounding terminals, all housed within a padlockable enclosure.

D. Power from a portable generator shall only be permitted by means of a key interlock system with the permanent generator to prevent both power sources being connected together.

E. Dual purpose docking station enclosure shall be Type 3R, constructed of continuous seam-welded, powder coated galvanneal steel or stainless steel per the drawings.  The main access shall be through a hinged door that extends the full height of the enclosure.  Access for both portable generator cables with female cam-style plugs and for load bank cables with male cam-style plugs shall be via a hinged lower flap door.  Hinged flap door shall be provided to cover the cable openings when cables are not connected; the hinged flap door shall allow cable entry only after the main access door has been opened.  Enclosure shall be powder coated after fabrication; color shall be wrinkle gray RAL 7035.

F. Cam-style male connectors (inlets) and cam-style female connectors (outlets) shall be UL Listed single-pole separable type and rated 400 amps at 600VAC.  All cam-style connectors shall be color coded.  Cam-style connectors shall be provided for each phase and for ground, and shall also be provided for neutral (if required).  Each of the phase cam-style connectors and the neutral cam-style connectors within the enclosure shall be factory-wired. The ground cam-style male connectors shall be bonded to the enclosure, and a ground lug shall be provided for connection of the facility ground conductor.

G. Termination lugs shall be provided for line and load-side field wiring

H. Molded case circuit breakers shall be UL Listed 3-pole and the short circuit interrupt rating shall be per the drawings. Trip rating of the molded case circuit breakers shall be as shown on the drawings.

SECTION 3 – EXECUTION

3.01 Installation:

A. Prior to installation of dual purpose docking station, Contractor shall examine the areas and conditions under which the dual purpose docking station is to be installed and notify the Engineer in writing if unsatisfactory conditions exist.

B. Dual purpose docking station shall be installed as shown on the drawings and per the manufacturer’s written instructions.  In addition, the installation shall meet the requirements of local codes, the National Electrical Code and National Electrical Contractors Association’s “Standard of Installation”.

C. Conduit entry into the dual purpose docking station shall be by Contractor; Contractor shall furnish and install listed watertight conduit hubs, as manufactured by MYERS or T&B, for each conduit entry on the dual purpose docking station.  The incoming hub size shall match the conduit size for feeders and ground as shown on the drawings.  The outgoing hub size shall match the conduit size for loads and ground as shown on the drawings.  Hubs shall be properly installed and tightened to maintain Type 3R integrity of the dual purpose docking station enclosure.

D. Contractor shall terminate feeder conductors, load conductors and ground per the manufacturer’s instructions.  All field wiring terminations shall be torqued as required per the instructions on the dual purpose docking station ’s termination lugs, circuit breakers & ground lugs.

3.02 Field Testing:

A. Prior to energizing dual purpose docking station, the Contractor shall perform the following checks and tests as a minimum:
1. Verify mounting and connections are complete and secure.
2. Verify internal components and wiring are secure.
3. Perform continuity check of all circuits.
4. Perform 1,000 VDC megger test on feeder and load cables. Prior to testing, all auxiliary circuits must be turned OFF and all fuses, microswitches and shunt trip circuits must be disconnected. It is required to take out the rating plug of any electronic trip circuit breakers while performing a megger (insulation) test.
5. Verify deadfront is secure.
6. Confirm operation of the dual purpose docking station ground receptacle by attaching a plug to the dual purpose docking station ground receptacle and then verify that the plug is grounded to the facility ground.

End of Section

Contact

ESL Power Systems, Inc.
2800 Palisades Drive | Corona, CA 92878-9427
t: (800) 922-4188 | +1 (951) 739-7000
info@eslpwr.com

Follow

  • LinkedIn
  • RSS
  • YouTube

Have a question?

To receive additional information on ESL’s products or services fill out our request information form here.

Copyright © 2026 | ESL Power Systems, Inc. | Privacy Policy | Terms of Use

This site uses cookies to give you the best, most relevant experience. Continuing to browse this site or clicking “OK,” means you agree to this. To learn more about how to change your cookie settings, please see our privacy policy.OKPrivacy policy